Mechanical characteristics changes before and after cladding
| Materials | Thickness (mm) | Hardness (Hv) | Tensile strength (N/mm²) | |
|---|---|---|---|---|
| Before cladding | SUS304 | 0.201 | 170 | 703 |
| AI 1N99 | 0.056 | 24 | 59 | After cladding | SUS304 | 0.200 | 173 | 572 (*) |
| AI 1N99 | 0.055 | 25 |
* Strength as cladding material
- There are no characteristics changes before and after cladding as shown in the table above.
Process Example
![]() |
![]() |
| Bending test cross-section 35 µmCu/0.26 mmSteel/35 µmCu |
Cladding material process example Al/mild steel clad Cu/SUS/Al clad Ti/Al/SUS clad |